The SETUP02 Item is used to setup a new patient with Oxygen for the first time. These items used are setup on the Recipe tab of the SETUIP02 Item, consisting of the Oxygen Concentrator, Tubing, Canula, Warning Sign, Oxygen wrench, Portable and OCD (Oxygen Conserving Device). Then on this tab, these Items would be modified.
| Item Number | Description | UM | TOS | Allowed Bilings | HCPCS | Allowable | Special Price | |
| 1 | SETUP02 | Oxygen Concentrator Setup | EA | 12 | 0 | 2-0.00 | 1-0.00 | |
| 2 | Oxygen Concentrator | 18 | 36 | E1390RR | 1-0.00 | 0-0.00 | ||
| 3 | SLT1600 | Canula, Nasal, Salter Adult | EA | 12 | 0 | |||
| 4 | W156 | Oxygen Warning Sign | EA | 12 | 0 | |||
| 5 | W199 | Oxygen Wrench | EA | 12 | 0 | |||
| 6 | INVMS4121 | Tubing, Disposable Oxygen 25′ | EA | 12 | 0 | |||
| 7 | HP4111 | Ox Shoulder Pack w/D Cylinder | EA | 18 | 36 | E0431RR | ||
| 8 | IRC2002 | Piston Regulator with Contents Gauge | EA | 18 | 36 |
1. First we modify the Kit Item Number to change it from a Rental to a Purchase. This means the Item is not transferred to the Recurring Order for the Patient.
2. Then we add a second Item with a blank (virtual) Item Number and a Procedure code of E1390RR. This will be replaced with the Item Number of the Oxygen Concentrator we provide, whether from Invacare, Sunrise or Airsep.
3-6. We convert these items from 18 to 12 to indicate a purchase.
7-8. We mark these items with an Allowed Billing of 36 to put them on the Recurring Order.